dc.description.abstract |
According to the codes of practice for design of concrete structures, the effect of solar
radiation has to be given due consideration. However, it is not specifically incorporated in
the structural design. Often providing expansion or sliding joints is the common practice to
accommodate the effect of solar radiation. The need to provide reinforcement bars at tensile
stress regions where thermal stresses may develop within the design life of the structure is
currently an undocumented fact.
Therefore the main aim of this research was to investigate the significance of solar
radiation effect on concrete water retaining structures and to highlight the occurrence of high
stress zones that need attention. The investigation was performed using a finite element
model with gathered solar radiation data. The model was simulated with probable thermal
properties of concrete and environmental conditions including solar heat flux, to identify the
governing parameters.
In order to process large amounts of data and for economic reasons, a finite element
method of analysis using ANSYS software was considered. This provided the robustness and
contributed to focus on the sensitivity of the parameters under investigation. Further, several
simplified models were verified with numerical calculations and compared with the finite
element model. Characteristic points on stress response curve from the finite element
analysis were compared with the numerical results. Comparisons were made with respect to
the accuracy and reliability of using the finite element model for the analysis.
Based on the verified modeling approach, a typical underground water tank was
investigated for sliding and fixed roof slab to wall connectivity. The temperature variation
and corresponding stress variations were obtained.
It was found that significantly high tensile stresses are developed at the soffit level of
the roof slab near the column heads, where normally only compressive stresses are expected.
This occurs for both fixed and sliding roof slab-to-wall connections. Also at the mid spans,
as the top surface of the roof slab was being compressed due to thermal expansion, the
bottom surface was not being compressed due to the comparatively low temperature than the
top surface (i.e. the temperature gradient). Therefore the bottom fibers developed tensile
stresses, which was significantly more than the tensile stress due to selfweight only.
It is conclusive that the solar radiation is significant on concrete water retaining
structures and the use of sliding or fixity conditions between the roof slab and wall is not
effective in minimizing the tensile stresses due to solar heat gain; |
en_US |