Institutional-Repository, University of Moratuwa.  

Investigation of the most effective method of installing CFRP strips in retrofitting concrete beams

Show simple item record

dc.contributor.author Amarasinghe, NA
dc.contributor.author Gamage, JCPH
dc.date.accessioned 2018-06-14T20:23:31Z
dc.date.available 2018-06-14T20:23:31Z
dc.identifier.uri http://dl.lib.mrt.ac.lk/handle/123/13193
dc.description.abstract This paper is based on an experimental analysis carried out in order to identify the best method of installation of CFRP strips to enhance the flexural capacity of a reinforced concrete beam. Of the two me“ot installation; EBR (externally bonded reinforcement) and NSM (Near surface mounted) the NSM me o as been proven to be better in qualitative terms. The research gap of quantitative validation of this concept is fulfilled by this research paper. Two new methods of integration of EBR and NSM method were also experimented with the objective of increasing the flexural capacity of reinforced concrete elements by increasing the effective area of CFRP strips used. Suggestions to eliminate the failure modes observed in theexperiment and to enhance the flexural capacity are also discussed in this paper. en_US
dc.language.iso en en_US
dc.title Investigation of the most effective method of installing CFRP strips in retrofitting concrete beams en_US
dc.type Conference-Abstract en_US
dc.identifier.faculty Engineering en_US
dc.identifier.department Department of Civil Engineering en_US
dc.identifier.year 2015 en_US
dc.identifier.place Moratuwa, Sri Lanka en_US
dc.identifier.pgnos pp. 21 - 24 en_US