Microstrip patch antenna for partial discharge detection as a condition monitoring tool of power system assets

Show simple item record

dc.contributor.author Ediriweera, weps
dc.contributor.author Priyanayana, KS
dc.contributor.author Rajakaruna, RMAP
dc.contributor.author Ranasinghe, Rakg
dc.contributor.author Lucas, JR
dc.contributor.author Samarasinghe, R
dc.date.accessioned 2018-08-21T19:33:54Z
dc.date.available 2018-08-21T19:33:54Z
dc.date.issued 2017
dc.identifier.uri http://dl.lib.mrt.ac.lk/handle/123/13415
dc.description.abstract An electric power system consists of a number of critical and expensive equipment that operate under high electric stresses. Failure of such an asset can lead to unscheduled interruptions and incur huge economic losses. Partial Discharges are considered as one of the main causes of degradation of electrical insulation in any power system asset. Frequent and successive occurrence or extensive levels of partial discharge activity can damage power system components, and even lead to hazardous events which affect mankind. Therefore, it is recommended to use partial discharge detection as a condition monitoring technique in order to ensure the reliability of these assets. This gives the asset management engineers adequate warning to take necessary actions to rectify the situation if the equipment are found to be faulty. In this paper, a Micro-strip Patch Antenna has been designed using radio frequency method, in order to detect electromagnetic waves that occur due to the partial discharge activity in power system assets. This paper discusses the design specifications, experimental procedure, observations and results involved with partial discharge detection using a microstrip patch antenna, which is a cost effective, noncontact, reliable and online condition monitoring method for certain types of power system assets. en_US
dc.language.iso en en_US
dc.subject Partial Discharge; Microstrip Patch Antenna; Radio Frequency method; Power System Assets en_US
dc.title Microstrip patch antenna for partial discharge detection as a condition monitoring tool of power system assets en_US
dc.type Conference-Abstract en_US
dc.identifier.faculty Engineering en_US
dc.identifier.department Department of Electrical Engineering en_US
dc.identifier.year 2017 en_US
dc.identifier.conference Moratuwa Engineering Research Conference - MERCon 2017 en_US
dc.identifier.place Moratuwa, Sri Lanka en_US
dc.identifier.email sampath_ediriweera@gmail.com en_US
dc.identifier.email sahan.priyanayanarr@gmail.com en_US
dc.identifier.email rmapasidu@gmail.com en_US
dc.identifier.email kasungr1992@gmail.com en_US
dc.identifier.email lucas@elect.mrt.ac.lk en_US
dc.identifier.email rasara@elect.mrt.ac.lk en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record