Show simple item record

dc.contributor.advisor Nanayakkara, DPN
dc.contributor.author Chandranath, MLAA
dc.date.accessioned 2011-06-24T06:18:52Z
dc.date.available 2011-06-24T06:18:52Z
dc.identifier.citation Chandranath, M.L.A.A. (2004). Analysing of power quality problems of wind power generators [Master's theses, University of Moratuwa]. Institutional Repository University of Moratuwa. http://dl.lib.mrt.ac.lk/handle/123/1354
dc.identifier.uri http://dl.lib.mrt.ac.lk/handle/123/1354
dc.description.abstract Wind power as a rule does not contribute to voltage in grids. Also, wind power very often is a source of voltage fluctuations and flicker. Furthermore, care must be taken to upkeep availability of networks more or less dependent on wind power by preventing the voltage from collapsing in conjunction with faults occurring in the grid. The first wind power plant installed at Hambantota III Sri Lanka, 3MW was commissioned in early 1999. Alternating current transmission will turn out to be an economically and technically attractive option in many cases, and dynamic reactive power compensation will then be a natural part of the scheme. The dominating kind of wind power generators are asynchronous, this since they are robust and cost effective. Induction generators, however, do not contribute regulation of grid voltage nor frequency, and they are substantial absorbers of reactive power. Ideally, they need to be connected to very stiff grids in order not to influence power quality is a detrimental way. This is not the case in reality. Quite 0 n the contrary, wind power is usually connected for out in the grid, on sub transmission or distribution levels. The majority cases are 10-40kV. The objective of the research is to analyze the problem of voltage and current harmonics, transient behavior, power fluctuation and reactive power consumption of wind power generators and modeling of wind turbines connected to the medium voltage distribution line of the grid wher~ the other consumers are connected. Often, Voltage regulation problems arise as a consequence of grids being made dependent on wind power, a matter of growing concern as wind power gets more important in the power balance. To certain degree, Voltage Control problems cased by defect of reactive power in the grid can be, and is remedied by installation of fixed or mechanically switched shunt capacitors. This will 'not help on voltage fluctuations, however caused by varying output of wind generators. Regular voltage flicker is part of the picture, as well, caused by such phenomena as turbulent wind impact and so-called tower shadow effects.
dc.language.iso en en_US
dc.subject ELECTRICAL ENGINEERING-THESIS
dc.subject THESIS-ELECTRICAL ENGINEERING
dc.subject power quality analysis
dc.subject WIND POWER GENERATION
dc.title Analysing of power quality problems of wind power generators
dc.type Thesis-Abstract
dc.identifier.faculty Engineering en_US
dc.identifier.degree MEng en_US
dc.identifier.department Department of Electrical Engineering en_US
dc.date.accept 2004
dc.identifier.accno 82485 en_US