Experimental study on reinforced concrete columns partially confined with carbon fiber reinforced polymer (CFRP)

Show simple item record

dc.contributor.author Lewangamage, CS
dc.contributor.author Rankoth, CK
dc.contributor.author Sanjeewani, DMDN
dc.date.accessioned 2019-10-28T04:25:20Z
dc.date.available 2019-10-28T04:25:20Z
dc.identifier.uri http://dl.lib.mrt.ac.lk/handle/123/15223
dc.description.abstract The requirement of strengthening of reinforced concrete structures may emerge not only due to timed degradation but also due to various reasons like construction faults, increased loads and changes in utilization purpose etc. Rehabilitation of reinforced concrete structures using Carbon Fibre Reinforced Polymer materials is recognized as a very effective retrofitting method. The current practice on strengthening reinforced concrete columns with external CFRP jacketing is to provide full wrapping all over the column with less care on the required strength increment As CFRP is a costly material, providing partial wrapping may be a viable option for cost reduction rather than providing full confinement. An experimental study was carried out with 17 specimens to study the partial confinement effect. The test specimens consist of 6 plain concrete columns with 3 control specimens and 3 fully confined columns. 11 reinforced concrete columns with 3 control specimens, 3 columns with full confinement and 5 columns with partial confinement. Two wrapping patterns were used for partially confined columns with 75mm and 50mm laminate width, keeping the volumetric ratio of CFRP constant to study the effect of wrapping pattern and jacket location for strength and ductility increment. The results of experimental study revealed that the load carrying capacity increment for fully wrapped reinforced concrete columns were 100% while for plain concrete columns it was 47% and for partially confined columns, the specimens with two 75mm wraps showed a capacity increment of 59% while specimens with three 50mm wraps showed an increment of 83%. It was observed that, by only changing the jacket location 15% ultimate load carrying capacity increment can be obtained. When ductility increment is considered it was observed that ductility increment is proportional to the strength increment. en_US
dc.language.iso en en_US
dc.subject Reinforced concrete column, CFRP, Partial confinement, Strength, Ductility en_US
dc.title Experimental study on reinforced concrete columns partially confined with carbon fiber reinforced polymer (CFRP) en_US
dc.type Conference-Abstract en_US
dc.identifier.faculty Engineering en_US
dc.identifier.department Department of Civil Engineering en_US
dc.identifier.year 2013 en_US
dc.identifier.conference 4th International Conference on Structural Engineering and Construction Management - 2013 en_US
dc.identifier.pgnos pp. 1 - 11 en_US
dc.identifier.proceeding Special Session on Construction Materials & Systems, en_US
dc.identifier.email suieewal@uonLlk en_US
dc.identifier.email chamilakr@gmail.com en_US
dc.identifier.email dmdnsaniu@,gmail.com en_US