Institutional-Repository, University of Moratuwa.  

Development of hybrid islanding detection technique for distributed power generation

Show simple item record

dc.contributor.advisor Perera, R
dc.contributor.author Tilakeratne, RP
dc.date.accessioned 2011-07-14T08:43:10Z
dc.date.available 2011-07-14T08:43:10Z
dc.identifier.citation Tilakeratne, R.P. (2008). Development of hybrid islanding detection technique for distributed power generation [Master's theses, University of Moratuwa]. Institutional Repository University of Moratuwa. http://dl.lib.mrt.ac.lk/handle/123/1637
dc.identifier.uri http://dl.lib.mrt.ac.lk/handle/123/1637
dc.description.abstract The utilization of distributed generation (DG) units is rapidly increasing in power system and questions are raised regarding their effect on the system, energy management and protection policies. DG can provide in some cases a significant art of the load energy requirements. Islanding operation of DG usually occur when the main utility supply is interrupted due to several contingencies (inrush currents, faults, etc) while the DG is still supplying power to the distribution network at a sustained voltage and frequency. These conditions have negative impacts on the system protection, restoration, operation and management and could be fatally harmful to line workers and power system facilities. IEEE Std. 1547TM-2003 & IEEE Std.929-2000 require that islanded DG system be shut down within a specified time. Therefore, it is necessary to detect the presence of this condition and switch off the DG from distribution network or isolate the DG with its load from the rest of the system. Conventional detection methods for islanding conditions are based on monitoring several parameters such as voltage magnitude, phase, displacement, frequency change, voltage unbalance (VU) and total harmonic distortion (THD). However, in case of small changes in loading for DG, the contingency will be masked by normal operating condition. Conventional methods usually will not detect such an islanding condition. Among the existing islanding detection techniques, two techniques, namely the positive feedback (PF) technique and voltage unbalance and the total harmonic distortion (VU/THD) technique are most promising ones. However, both of these tecliniques have their own flaws. In this thesis a new technique is proposed that combines the principles of those two to obtain a hybrid islanding detection technique for synchronously rotating DGs. Simulation results show that the proposed hybrid technique is more effective than each of the above schemes
dc.language.iso en en_US
dc.subject ELECTRICAL ENGINEERING - Thesis
dc.subject ELECTRICAL INSTALLATIONS - Thesis
dc.subject ELECTRIC POWER GENERATION
dc.title Development of hybrid islanding detection technique for distributed power generation
dc.type Thesis-Full-text
dc.identifier.faculty Engineering en_US
dc.identifier.degree MSc en_US
dc.identifier.department Department of Electrical Engineering en_US
dc.date.accept 2008
dc.identifier.accno 93954 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record