Abstract:
A mathematical formula was derived to predict the
porosity of pervious concrete (PC) at its fresh state. Coarse
aggregates (CA) within the size ranges of 0.016-0.02m and 0.01-
0.014m were used in the study. Pervious concrete was mixed for
two stages. A w-c ratio of 0.3 was used in the study. A scaling factor
was defined to represent the thickness of cement paste coated
around CA. The scaling factor is independent of the size of CA
used and their volume based binary combinations. The percentage
difference between the two scaling factor values obtained for CA
having a size of 0.01-0.014m was calculated to be 1.14 percent. The
tested wet density in all PC batches made in the first stage was
approximately 170-264kg/m3 lesser than the designed wet density.
The difference between the tested porosity values and the porosity
values calculated by the mathematical model has been developed
is approximately 0.01-0.015m3 for all pervious concrete batches. It
was observed that as the scaling factor increases the wet density
increases and the porosity reduces. The porosity values calculated
by the mathematical model and the tested porosity show a very
strong linear relationship.
Citation:
A. B. Y. Kariapper and D. Nanayakkara, "A New Approach to Predict the Porosity of Pervious Concrete at Its Fresh State," 2018 Moratuwa Engineering Research Conference (MERCon), 2018, pp. 173-178, doi: 10.1109/MERCon.2018.8421982.