Institutional-Repository, University of Moratuwa.  

Retrofitting of punching shear damaged flat slabs using carbon fiber reinforced polymer (CFRP) sheets

Show simple item record

dc.contributor.advisor Gamage JCPH
dc.contributor.author Priyanjani VGM
dc.date.accessioned 2021
dc.date.available 2021
dc.date.issued 2021
dc.identifier.citation Priyanjani, V.G.M. (2021). Retrofitting of punching shear damaged flat slabs using carbon fiber reinforced polymer (CFRP) sheets [Master's theses, University of Moratuwa]. Institutional Repository University of Moratuwa. http://dl.lib.uom.lk/handle/123/20706
dc.identifier.uri http://dl.lib.uom.lk/handle/123/20706
dc.description.abstract The punching shear failure of flat slabs is common in reinforced concrete buildings, and once the failure occurs, rectification is difficult and time consuming, which also affects building functionality. Hence, it is convenient to retrofit the flat slab structure to enhance the punching shear capacity while minimizing the disturbance to the structure. Therefore, a method was developed to retrofit punching shear damaged flat slabs using Carbon Fiber Reinforced Polymer (CFRP) sheets, considering the advantageous properties of the material, like the flexibility of usage, less weight, less thickness of material etc. Thus, experimental and theoretical studies were carried out using 12 numbers punching shear failed flat slab panels with various repair materials and various CFRP sheet arrangements. The BS EN 1992-1-1: 2004 standard was used for theoretical analysis. A comparison of theoretical and experimental punching shear capacities concluded that the theoretical capacity is much higher than the experimental capacity, due to the difference of failure modes of the specimens. en_US
dc.language.iso en en_US
dc.subject REINFORCED CONCRETE BUILDINGS en_US
dc.subject SHEAR DAMAGED FLAT SLABS en_US
dc.subject CARBON FIBER REINFORCED POLYMER (CFRP) SHEETS en_US
dc.subject RETROFITTED FLAT SLABS en_US
dc.subject FIBER REINFORCED POLYMER en_US
dc.subject PUNCHING SHEAR FAILURE en_US
dc.subject CIVIL ENGINEERING-Dissertation en_US
dc.subject STRUCTURAL ENGINEERING -Dissertation en_US
dc.title Retrofitting of punching shear damaged flat slabs using carbon fiber reinforced polymer (CFRP) sheets en_US
dc.type Thesis-Abstract en_US
dc.identifier.faculty Engineering en_US
dc.identifier.degree MSc in Structural Engineering Design en_US
dc.identifier.department Department of Civil Engineering en_US
dc.date.accept 2021
dc.identifier.accno th4564 en_US


Files in this item