Institutional-Repository, University of Moratuwa.  

Numerical modeling of the flow field for indoor thermal comfort of a building under stack effect

Show simple item record

dc.contributor.advisor Attalage, RA
dc.contributor.advisor Perera, KKCK
dc.contributor.author Nimarshana, PHV
dc.date.accessioned 2015-11-27T12:07:25Z
dc.date.available 2015-11-27T12:07:25Z
dc.date.issued 2015-11-27
dc.identifier.uri http://dl.lib.mrt.ac.lk/handle/123/11527
dc.description.abstract In recent years natural ventilation is widely recognised as excellent contributing towards in design low energy buildings. The main challenge in natural ventilation is identified as lack of knowledge in providing acceptable thermal comfort in an occupied space to meet the internal requirements against the prevailing climatic conditions variations. Numerical investigations of the indoor thermal comfort condition in a simple office space governed by the solar chimney stack effect have been undertaken using CFD techniques. A mathematical model was developed based on the relevant analytical framework governing the phenomena to simulate the velocity flow field and temperature distribution on the designated plane within the indoor space. Boussinesq approximation was incorporated to numerical scheme with realistic boundary conditions for flow simulation. The model was enriched by incorporating a sufficient fluid volume to represent environment surrounding the space and thereby eliminating the entry effect to the flow. Hexahedral cells were used in a non-uniform grid distribution to minimise numerical diffusion. A fine mesh is used near the walls to enhance the resolution and accuracy resolving the problems under the turbulent flow conditions. Grid independence analysis was carried out to ensure the accuracy of the numerical results. Under-relaxation factors 0.3, 1, 2, 0.8, 0.8, 1, 0.9 for pressure, density, momentum, turbulence kinetic energy, turbulence dissipation rate, turbulent viscosity, energy respectively were used. The model outputs were compared with the available experimental measurements taken under the same condition to calibrate the numerical scheme. A parametric study was carried out using the calibrated model to assess the distribution of thermal comfort index against the changes in geometrical and solar radiation parameters. The values of activity, metabolic rate for seated activity and clothing insulation were selected as 0, 60 W/m2 and 0.5 Clo respectively for thermal performance analysis. The effect of each input parameter was investigated in terms of mean value and standard deviation corresponding to the flow velocity and the PPDNV value. It can be concluded that the present model is capable of predicting the indoor thermal performance of a building under stack effect. en_US
dc.language.iso en en_US
dc.subject Natural ventilation en_US
dc.subject MECHANICAL ENGINEERING
dc.subject VENTILATION
dc.subject COMPUTATIONAL FLUID DYNAMICS
dc.subject Solar chimney
dc.title Numerical modeling of the flow field for indoor thermal comfort of a building under stack effect en_US
dc.type Thesis-Full-text
dc.identifier.faculty Engineering en_US
dc.identifier.degree MSc (Major Component Research)
dc.identifier.department Department of Mechanical Engineering en_US
dc.date.accept 2015-04
dc.identifier.accno 109261 en_US